SKILLMO C3525E LCD Solar Power Plant (Roof Top) for ONGRID System, Single Phase 4 kw power with voltage 240 V

Skillmo

Product Code: SKILLMO Roof Top Mounting Structure

₹25900

Description


A Grid Tied Photo Voltaic (SPV) power plant consists ofSPV array, Module Mounting Structure, Power Conditioning Unit (PCU) consisting of Maximum Power Point Tracker (MPPT), Inverter, and Controls and Protections, interconnect cables and switches
PV Array MountingMounted on a suitable structure
Grid tied SPV system isWithout battery and designed with necessary features to supplement the grid power during day time.
Components and parts used in the SPV power plants including the PV modules, metallic structures, cables, junction box, switches, PCUs etc.,as per relevant BIS or IEC or international specifications,as applicable
Installation and testing for complete systemYes including Civil Work, Designing, Fabrication, Cabling Work with suitable Bolts, Nuts, Clamps, Connectors and testing etc.,

INVERTER

Rated out put power of inverter (Kw)4
Switching deviceMOSFET
No. of Phase (in Nos.)1
Inverter output wave formPure sine wave
TechnologyMPPT Based
No.of MPPT per inverter (in Nos.)1
No. of string at input side of inverter ( input port +ve and -ve) ( hint: 1 sets contains 1 +ve and 1 -ve port)1 set
Maximum power point trackerIntegrated in the PCU/inverter to maximize energy drawn from the array
Operating Voltage Range of Inverter50 V to 500 V
Over load support at Input side, DC15% of Maximum Input Voltage
Maximum input current for each MPPT (in A)11
Service conditionIndoor
Ingress protection rating of inverterIP 65 (for outdoor use)
Cooling medium for inverterNature air cooled
Manual switch for disconnecting DC supplyNo
Inverter mounting typeWall Mounted
Standard accessories for InverterMC4 DC Connectors, AC Connectors, Mounting bracket, Nuts and Bolts and inverter manuals
Isolation between input DC and output ACYes

INVERTER OUT PUT

Maximum current for single phase inverter (in A)5.2
Output voltage (in V)240 V
Invert auto trip at output sideLower : at 160 V, Higher : at 285 V with adjustable
Frequency range50 Hz +/-3
Grid Frequency Synchronization range+ 3 Hz or more
Grid Voltage tolerance-20% and +15%
Overall Efficiency (in %)>90
Efficiency Measurements for Power conditioners / Invertersas per IEC 61683 / IS:61683
Environmental Testing for Power conditioners / Invertersas per IEC 60068-2 (1,2,14,30) /Equivalent BIS Std.
PCU/inverter shall be capable of complete automatic operation forwake-up, synchronization and shutdown.

PROTECTION FOR INVERTER

Out put over current protectionYes
Out put over voltage protectionYes
Short circuit protectionYes
Overlod protection110% for 1 Minute,,125% for 30 sec.,,150% for 5 sec.
Over temperature protectionYes at 65 Deg. C Cooling Fan will auto switch ON
Surge protectionMetal Oxide Varistor (MOV)
Insulation Resistance MonitoringYes
Grid Monitoring protectionYes
THD (in %)<1.5%
Power factor at rated out put power0.8
Inverter body materialAluminium Casting

SERVICE CONDITION

Operating temperature-25 to +60 deg. C
Relative Humidity (in %)> 95 % non condensing
Maximum altitude above sea level (in m)4000

DISPLAY FEATURES ON INVERTER

Type of displayLCD
Display parametersDC Voltage,DC Current,AC Voltage,AC Current,Out put frequency,Power Factor
Display for Generating power dataDaily, Weekly, Monthly, Yearly with total generation
Generating power Data storage facilityYes for 2 Years from the date of commissioning
Interface facility for transmitting the generating power data for cloud storageInbuilt Wifi Enabled
Net meterApproved by Government of India/State Government authority concerned for connecting to Grid

Add on items - DC DISTRIBUTION BOARD

DC Distribution panel to receive the DC output from the array fieldYes with surge arrestors
Ingress protection (Enclosure protection) of DC Distribution BoxIP65
Material of bus bar and sizeCopper, size as per inverter rating
Circuit Breaker for input side (DC side) for each inverterMCB 10 A

Add on items - CABLE FOR INPUT

ISI Marked Connecting cables according to Inverter rating for each systemPV Module to Inverter DC
Electric Cable for Input1C x 6 Sq. mm, Copper Cable (as per IS:694:2010 latest)
Cable Length for PV Module to Inverter, DC (in m)5

Add on items - AC DISTRIBUTION BOARD

AC Distribution Panel Board (DPB) for controlling the AC power from PCU/inverter1 Phase 230 Volt +/- 10%, 50 HZ +/-3%
Panel constructionMetal clad, totally enclosed, floor mounted, air insulated, cubical type with change over switch
Ingress protection (Enclosure protection) of AC Distribution BoxIP54 for Indoor
All switches and the circuit breakers, connectors should conform toIS:60947 part I, II and III
Panels designed for minimum expected ambient temperature45 deg. C
Circuit Breaker for output side (AC side) for each inverterMCB 10 A

Support